Strona 1 - TRIPLETT

TRIPLETTModel310-TEL Type 3Hand-Sized VOM Instruction ManualTRIPLETT

Strona 2 - TABLE OF CONTENTS

10SPECIFICATIONS DC VoltsRanges: 0-3, 15, 60, 300 (20,000 ohms per volt)Accuracy:±3% of full scale valueAC VoltsRanges: 0-3, 15, 60, 300 (5,000 ohms p

Strona 3 - WARNING

11Meter50 µA - 250 mV (Pivot and Jewel)Overload ProtectionMeter movement protected by diodes.RX1 range protected by fuse.Voltage ranges protected by h

Strona 4

12GENERAL INSTRUCTIONS Control Locations For a diagram of the Model 310-TEL, please refer topage 15.Test Leads Check the test leads periodically. Lea

Strona 5

13Scale Selection Readings are taken on the scale having the appropri-ate significant figures (both 3 and 300 volts are readon the 0-300 scale) by mul

Strona 6

14Other Considerations Readings on the sensitive voltage, current and resis-tance ranges may sometimes be different than calcu-lated values. Thermo-e

Strona 7 - SAFETY CHECK

15COM V-O-MO∞ACV31560300OHMSADJUSTCONTROLPOLARITYREVERSINGSWITCHOHMSX1KX100X10X131560DCV300MA.6660600BLACKTEST LEADINPUTJACKDIAL SCALEINDICATORNEEDLEZ

Strona 8 - SAFETY IS NO ACCIDENT

16DC VOLTAGE MEASUREMENTS0-3 through 0-300 Volts:1. Insert the test leads into the appropriate jacks. (Red to V•O•M, Black to COM)2. Set Range S

Strona 9 - INTRODUCTION

17DC VOLTAGE MEASUREMENTSCOM V-O-MO∞SAFETY FIRST!31560DCV300+OHMSADJUSTCONTROLPOLARITYREVERSINGSWITCH

Strona 10 - SPECIFICATIONS

18AC VOLTAGE MEASUREMENTS0-3 through 0-300 Volts:1. Insert the test leads into the appropriate jacks. (Red to V•O•M, Black to COM)2. Set Range S

Strona 11

19AC VOLTAGE MEASUREMENTSCOMV-O-MO∞SAFETY FIRST!ACV31560300OHMSADJUSTCONTROLPOLARITYREVERSINGSWITCHSet Rangeto300 ACV

Strona 12 - GENERAL INSTRUCTIONS

2TABLE OF CONTENTS SAFETY RULES ... 3INTRODUCTION ... 9SPECIFIC

Strona 13 - Zero Adjustment

20RESISTANCE MEASUREMENTSX1 through X1K Ohms:1. Insert the test leads into the appropriate jacks. (Red to V•O•M, Black to COM)2. Set Range Switc

Strona 14 - Other Considerations

21RESISTANCE MEASUREMENTSCOM V-O-MO∞OHMSADJUSTCONTROLSAFETY FIRST!OHMSX1KX100X10X1POLARITYREVERSINGSWITCH

Strona 15 - CONTROL LOCATION DIAGRAM

22DC CURRENT MEASUREMENTS0-.6 through 0-600 Milliamperes:1. Insert the test leads into the appropriate jacks. (Red to V•O•M, Black to COM)2. Set

Strona 16 - DC VOLTAGE MEASUREMENTS

23DC CURRENT MEASUREMENTSCOM V-O-MO∞SAFETY FIRST!+–LOADMA.6660600OHMSADJUSTCONTROLPOLARITYREVERSINGSWITCH

Strona 17 - SAFETY FIRST!

24MEASURING OUTPUT VOLTS (dB)COM V-O-MO∞SAFETY FIRST!600ΩAUDIOAMPLIFIERACV31560300OHMSADJUSTCONTROLPOLARITYREVERSINGSWITCHTo read Output Voltage use t

Strona 18 - AC VOLTAGE MEASUREMENTS

25MEASURING OUTPUT VOLTS (dB)6MW 600Ω6MW 500Ω1MW 600ΩVOLTS100 10 190 9 .980 8 .870 7 .760 6 .650 5 .540 4 .430 3 .320 2 .210

Strona 19

26TRAHCNOITAREPOLET-013oTerusaeMegnaRhctiwSteSoTnOdaeRelacSelacShcaEslauqE.viDstloVCD3-051-006-0003-03VCD51VCD06VCD003VCD003 ÷ 0015106003tloV50.tloV52

Strona 20 - RESISTANCE MEASUREMENTS

27ACCESSORIES Carrying Cases:Model 369: Model 369-S:Cat. No. 10-1258 Cat. No. 10-1791Model 369-T: Case w/ Belt Loop:Cat. No. 10-1608 C

Strona 21

28Test Leads:79-153: 42” Test leads w/Screw-on Alligator Clips79-206: 48” Test leads with Alligator Clips (no probes)79-695: Test leads with Pin Cu

Strona 22 - DC CURRENT MEASUREMENTS

29Calibration With normal use, readjustment of this VOM shouldnot be necessary. An occasional check of the VOMagainst a known reference voltage or an

Strona 23

3SAFETY RULES • WARNINGThis tester has been designed with your safety in mind.However, no design can completely protect against in-correct use. Ele

Strona 24

30TRIPLETT LIMITED WARRANTY The Triplett Corporation warrants instruments and test equipment manufactured by it to befree from defective material or

Strona 26 - TRAHCNOITAREPOLET-013

Triplett Corporation One Triplett Drive Bluffton, OH 45817800-TRIPLETT FAX: 419-358-7956 www.triplett.com© Triplett Corpor

Strona 27 - ACCESSORIES

4• Do not use this meter with its battery cover open, its rear case open, or with parts removed.• Do not open this meter for maintenance without f

Strona 28 - MODEL 310-TEL

5• Make sure both test leads are fully inserted into their respec- tive input jacks (Black lead into COM and Red lead into V•O•M). A loose test

Strona 29 - Calibration

6• Do not use the meter if it does not appear to work correctly on all ranges and in all modes.• Do not use the meter if it has undergone long-ter

Strona 30 - TRIPLETT LIMITED WARRANTY

7• Do not mistake a downscale reading as an indication that no potential is present. Dangerous potentials may be present that may result in user

Strona 31

8DO NOT TOUCH Do not touch exposed wiring, connections or other“live” parts of an electrical circuit. If in doubt, checkthe circuit first for voltage

Strona 32

9INTRODUCTION The Triplett Model 310-TEL is a handy hand-sized VOMwith all the versatility and performance of larger, moreexpensive bench-size models.